Entity: buildingEnergyProfile ​

Entity Type: Database table

Description: Current administrative and energy-related metadata for a building. Stores energy performance certificate data (PENB), programme enrolments (EPC, ISO, OPZP), installed power, and building envelope coefficients. One record per building (1:1 relationship). Versioned attributes are tracked in separate append-only history tables (see Note below); this table always reflects the latest state. A denormalised tenantId is stored so the table can carry a uniform Row-Level Security policy; the application keeps it consistent with the parent building.

Content resolution note: Confluence held two pages for this entity — the original buildingEnergyProfile (id 524845062, last modified 2026-06-16) and buildingEnergyProfile rev. 2 (id 554237957, last modified 2026-06-17). Rev. 2 is a superseding redesign of the same entity: it switches from an ad-hoc audit approach to an explicit "current + history" pattern and adds four append-only history tables. This document is migrated from rev. 2, the current/authoritative version; the original page's content is superseded and not separately preserved here.

Rev. 2 also defines four related append-only history entities (buildingEnergyProfilePenbHistory, buildingEnergyProfileEnvelopeHistory, buildingEnergyProfileProgramHistory, buildingEnergyProfileLightingHistory), each a child of this entity via buildingEnergyProfileId. These are genuinely separate database tables, not JSONB columns of buildingEnergyProfile, and were not in this migration's assigned page list — they are not documented as sibling files here and still need their own entity folders when migrated. See the Confluence source (rev. 2) for their full DATs in the meantime.

Data Attributes Table ​

Attribute NameDescriptionData TypeDefault ValueRequired (= Nullable)UniqueFormatValidationsIndexExample
idPrimary key of the entityUUIDGeneratedYesYesUUID v4-Primary Keya1b2c3d4-…
buildingIdThe building this profile belongs to. One profile per building.UUID-YesYesUUID v4Foreign Key → building; must exist; unique (1:1)name: idx_buildingEnergyProfile_buildingId, type: btreeb2c3d4e5-…
tenantIdTenant that owns this record. Denormalised from building for Row-Level Security. Must equal the parent building's tenantId; enforced by the application on insert.UUID-YesNoUUID v4Foreign Key → tenant; must exist; must equal parent building.tenantIdname: idx_buildingEnergyProfile_tenantId, type: btreee5f6a7b8-…
floorCountTotal number of above-ground floors in the building.IntegernullNoNosmallintMin 1-3
factorAvRatio of building envelope surface area to enclosed volume (A/V, m⁻¹). Used in energy performance calculations. Migrated as-is from legacy factor_av column on building_properties.DecimalnullNoNodecimal(10,4)Min 0-0.3500
installedPowerKwInstalled power of the main energy source (kW), parsed from legacy rated_power_source. Populated only when the legacy value could be parsed into a single numeric value. See installedPowerRaw for the original legacy string.DecimalnullNoNodecimal(10,2)Min 0-250.00
installedPowerUnitUnit of installed power, parsed from legacy rated_power_source (e.g. "kW", "kWh"). Populated only when the legacy value could be successfully parsed. Null when parse failed or legacy field was empty.StringnullNoNo-Max 20 characters-kW
installedPowerRawOriginal free-text value of legacy rated_power_source, migrated as-is. Preserved to avoid data loss when the value could not be parsed into a number + unit. Null when the legacy field was empty.StringnullNoNo-Max 255 characters-2x50kWh
uemCalculatedCalculated heat transfer coefficient of the building envelope (W/m²·K).DecimalnullNoNodecimal(8,4)Min 0-0.3200
uemReferenceReference heat transfer coefficient for a comparable standard building (W/m²·K).DecimalnullNoNodecimal(8,4)Min 0-0.4500
penbClassEnergy performance classification from the building's energy performance certificate (PENB).StringnullNoNo-One of: A, B, C, D, E, F, G-C
penbTotalEnergyPENB: total delivered energy demand (kWh/m²/year).DecimalnullNoNodecimal(10,2)Min 0-180.00
penbTotalEnergyRefPENB: reference value for total energy demand (kWh/m²/year).DecimalnullNoNodecimal(10,2)Min 0-200.00
penbNonRenewableEnergyPENB: non-renewable primary energy demand (kWh/m²/year).DecimalnullNoNodecimal(10,2)Min 0-150.00
penbNonRenewableEnergyRefPENB: reference value for non-renewable primary energy (kWh/m²/year).DecimalnullNoNodecimal(10,2)Min 0-170.00
penbHeatingConsumptionPENB: specific delivered energy for heating (kWh/m²/year).DecimalnullNoNodecimal(10,2)Min 0-90.00
penbHotWaterConsumptionPENB: specific delivered energy for hot water (kWh/m²/year).DecimalnullNoNodecimal(10,2)Min 0-30.00
rvoCountNumber of public lighting control cabinets (rozvaděče veřejného osvětlení). Applicable to buildings of type publicLighting only.IntegernullNoNo-Min 0; only valid when building.type = publicLighting-12
operatingTimeLegacy free-text description of the building's typical operating hours, migrated as-is from EM2. Non-binding — the structured schedule in buildingSchedule takes precedence in all system logic. Not versioned — stored only on the main entity.StringnullNoNo-Max 255 characters-Mo–Fr 07:00–18:00
classification1Custom classification label 1 (Jiné 1). Tenant-defined, free text.StringnullNoNo-Max 255 characters-Green building
classification1SinceDate from which classification1 applies.DatenullNoNoYYYY-MM-DD--2020-01-01
classification2Custom classification label 2 (Jiné 2). Tenant-defined, free text.StringnullNoNo-Max 255 characters-ISO 50001 scope
classification2SinceDate from which classification2 applies.DatenullNoNoYYYY-MM-DD--2021-06-01
epcEnrolledIndicates whether the building is enrolled in an Energy Performance Contracting programme.BooleanfalseYesNo---false
epcFromStart date of the EPC programme enrolment.DatenullNoNoYYYY-MM-DDRequired when epcEnrolled = true-2022-01-01
isoCertifiedIndicates whether the building holds an ISO energy management certification.BooleanfalseYesNo---true
isoFromDate from which ISO certification is valid.DatenullNoNoYYYY-MM-DDRequired when isoCertified = true-2021-06-01
opzpEnrolledIndicates whether the building is part of the OPZP environmental programme.BooleanfalseYesNo---false
opzpFromStart date of OPZP programme enrolment.DatenullNoNoYYYY-MM-DDRequired when opzpEnrolled = true-2020-03-15
legacyIdLegacy-system identifier; migration provenance.StringnullNoNo---5502
createdAtTimestamp of when the record was created.Timestampnow()YesNoYYYY-MM-DDTHH:mm:ss.SSS+00--2024-03-01T08:00:00.000+00
updatedAtTimestamp of the last update to the record.Timestampnow()YesNoYYYY-MM-DDTHH:mm:ss.SSS+00--2024-06-15T14:22:00.000+00
createdByIdentifier of the actor who created the record (user ID or system).StringsystemYesNo-Non-empty-user:a1b2c3d4 / system
updatedByIdentifier of the actor who last updated the record (user ID or system).StringsystemYesNo-Non-empty-user:a1b2c3d4 / system

Note: source page has no deletedAt column for this entity. Documented as given; not added.

Note: the rev. 2 source page's prose says attributes are "versioned in 5 logical groups" but only 4 history tables/groups are actually defined in the body (PENB, Envelope, Programmes, Lighting) — a discrepancy in the source itself, flagged here rather than guessed at.

Audited fields ​

Recorded on created (in full), updated (changed only) and deleted (in full): floorCount, factorAv, installedPowerRaw, installedPowerKw, installedPowerUnit, uemCalculated, uemReference, penbClass, penbTotalEnergy, penbTotalEnergyRef, penbNonRenewableEnergy, penbNonRenewableEnergyRef, penbHeatingConsumption, penbHotWaterConsumption, rvoCount, operatingTime, classification1, classification1Since, classification2, classification2Since, epcEnrolled, epcFrom, isoCertified, isoFrom, opzpEnrolled, opzpFrom, legacyId.

Excluded: none.

Not registered for entityName resolution — one row per building (buildingId unique); described via the building it belongs to, not a name of its own.